Minimal Maintenance. The imageCLASS MF3010 uses the all-in-one Toner Cartridge 325. The Canon all-in-one toner cartridge design integrates the. 1) Replace the Main Controller PCB. Canon MF3010 USM Ver.1.01 2) Connect the PC to this machine and start USM. Canon MF3010 Service Control Tool Set up CANON MFP ( USB Service Mode) 3) Display COPIER > TYPE. Page 127: Testmode.

• Code: E000 • Description: Startup failure • Remedy: (1) Check the connectors of the Fixing Assembly. (J101, J1011, J552 and J702) (2) Replace the Fixing Assembly. (3) Replace the Engine Controller PCB. • Code: E001 • Description: Abnormal high temperature • Remedy: (1) Check the connectors of the Fixing Assembly.

(J101, J1011, J552 and J702) (2) Replace the Fixing Assembly. (3) Replace the Engine Controller PCB. • Code: E003 • Description: Abnormal low temperature • Remedy: (1) Check the connectors of the Fixing Assembly. (J101, J1011, J552 and J702) (2) Replace the Fixing Assembly. (3) Replace the Engine Controller PCB. • Code: E004 • Description: Fixing heater drive circuit error (200V models only) • Remedy. • Code: E100 • Description: Scanner area failure • Remedy: (1) Check the connectors of the Fixing Assembly.

(J101, J1011, J552 and J702) (2) Replace the Fixing Assembly. (3) Replace the Engine Controller PCB.

• Code: E196 • Description: ROM read/write error (error in storing setting values in user mode/service mode/ factory mode) • Remedy: When the same error repeatedly occurs although the power is turned OFF and then ON for several times, execute the following remedies. (1) Update the firmware of the Main Controller PCB. (2) Replace the Main Controller PCB. • Code: E202 • Description: CIS Unit home position detection error / homeward reading position error • Remedy: When the same error repeatedly occurs although the power is turned OFF and then ON for several times, execute the following remedies. (1) Check the connection between the Main Controller PCB and the CIS Unit.

(J2) (2) Replace CIS Unit. (3) Check the connection between the Main Controller PCB and the Reader Motor (M3). (J11) (4) Replace the Reader Motor (M3). (5) Replace the Main Controller PCB. • Code: E225 • Description: Insufficient lamp light intensity (The light intensity is at the reference level or below.) • Remedy: When the same error repeatedly occurs although the power is turned OFF and then ON for several times, execute the following remedies. (1) Check the connection between the Main Controller PCB and the CIS Unit. (J2) (2) Replace CIS Unit.

(3) Replace the Main Controller PCB. Download free as400 tutorial for beginners pdf file.

This manual may contain technical inaccuracies or typographical errors due to improvements or changes in products. When changes occur in applicable products or in the contents of this manual, Canon will release technical information as the need arises. In the event of major changes in the contents of this manual over a long or short period, Canon will issue a new edition of this manual. The following paragraph does not apply to any countries where such provisions are inconsistent with local law. Of this manual. The following paragraph does not apply to any countries where such provisions are inconsistent with local law. U s e d t o s h o w p e r m i s s i o n.